Product details
Product Introduction
Frame Size: 116mm
Sash Size Series: 55mm
Equipped with 24mm thermal break strips.

Main Structure Material

  • Wall thickness: 1.8mm, compliant with new national standards.

Sash Design

  • Dual-cavity structure (indoor & outdoor), combined with 45° miter corner joining and glue injection technology, ensuring stable structure and high safety.

Frame Connection

  • 90° connection process for easy processing; frame and sash are flush indoors and outdoors for aesthetic appearance.

Fixed Sash Reinforcement

  • Multiple reinforced profile designs on the outdoor side, with high wind pressure resistance, suitable for various height divisions.

Functional Features

  • Upper positioning wheel design for smooth sliding.
  • 5mm translation locking for continuous sealing and excellent airtightness.
  • Quick-install hardware for convenient installation.

Sealing System

  • EPDM soft rubber strips for frame-sash sealing, with high deformation capacity to ensure sealing performance.

Size & Load Parameters

  • Minimum sash width: 500mm
  • Maximum width: calculated based on load-bearing capacity
  • Sash height: calculated based on sash weight and wind pressure resistance
  • Maximum sash weight: 100KG (with auxiliary wheels: up to 160KG)
    *Different sash heights, widths, and safety levels require matching hardware and profile configurations.
  • Compatible maximum glass thickness: 39mm

Performance Grades

  • Air tightness: Class 8
  • Water tightness: 500Pa (with additional lock points at 350mm sash height)
  • Wind pressure resistance: Class 9 (requires different reinforced profiles for different divisions)
  • Thermal insulation: Class 6 (K value 2.0~2.5 with low-e insulating glass)
  • Sound insulation: Class 4 (with insulating glass)